CK-MB brand | CK-MB manufacturer | CK-MB diagnostic reagents

CK-MB diagnostic reagents test results due to different representation method, biochemical analyzer test CK-MB for enzyme activity determination, measured values unit for U/L, and FIA8000 series of measurement for the quantitative analyzer immune quality determination, the unit of measurement for ng/ml. Domestic no quality determination of biochemical analyzer, so can't do P value calculation. For the measured results of CK-MB to do only correlation coefficient calculation. If considering CK-MB in biochemical analyzer test value be > 24 U/L is the positive, and FIA8000 > 5 ng/ml as positive, will be 24 U/L and value five ng/ml do a contrast, get a coefficient 4.8, will coefficient 4.8 when into consideration, and concludes that the P = 0.45., so P > 0.05, that there was no obvious difference.
CK-MB in biochemical analyzer test value be > 24 when U/L for positive, minimum detection limit 2 U/L; FIA8000 series immune quantitative analyzer test value > 5 ng/ml as positive, when measured values > 100 ng/ml, shows > 100 ng/ml, test value < 5 ng/ml show when < 5 ng/ml. CTnI such as described in 5.1, positive value > 1 ng/ml, negative value < 1 ng/ml. Myo in biochemical analyzer of positive on the boundary = 70 ng/ml, test value > 70 ng/ml positive, test value < 70 ng/ml for negative, but to FIA8000 series quantitative analyzer and supporting immune creatine kinase isozyme/myocardial ctni/muscle protein detection kit red one (colloidal gold method) speaking when test value > 50 ng/ml is concrete numerical display, when test numerical > 600 ng/ml, shows > 600 ng/ml.
In clinical trials of CK-MB positive samples to the 27 cases and the negative samples for 73 cases). CTnI positive samples for 17 cases and the negative samples for 83 cases). Myo positive samples for 17 cases and the negative samples for 83 cases. Creatine kinase isozyme/myocardial ctni/muscle protein detection kit red one (colloidal gold method) positive samples of 30 cases of accumulated.
Creatine kinase isozyme/myocardial ctni/muscle protein detection kit red one (colloidal gold method) qualitative diagnosis was 99% relative, including 100 patients with clinical samples CK-MB appear 1 official holiday positive.
Perlong medical treatment is the professional production CK-MB brand manufacturers, medical Triage heart failure of production perlong/mi diagnosis system can quantitative detection Myo (muscle red protein), CK-MB (creatine kinase isozyme), cTnI (cTnI) three cardiac muscle protein markers. Myo are of very high sensitivity, in the early diagnosis of MI and then stalks of capture is irreplaceable role,CK-MB is an important index quantification of myocardial infarction, can assist the diagnosis of MI degree and area, cIn I have unapproachable specificity and sensitivity, is the most important index of diagnosis MI. Myocardial injury in the test of all three projects have different advantages, united detection can be more comprehensive and accurate to assist the doctor diagnosed the illness.
If you want to know more details, you can login perlong medical equipment nets know more product information.