2016年6月19日星期日

rapid diagnostic test IL-6

Clinical Application of IL-6 Quantitative Detection Kit
1.Guidance in the using of the antibiotic
2. Newborn baby diagnostic indicator of the sensitivity of septicemia 
3. Early warning index of the SIRS and Sepsis
4. Early inspection symbol of acute inflammation
5. Quantitative indicator of the chronic inflammation
Advantage of rapid diagnostic test:
1. Linearity range: 2.0pg/ml~1500pg/ml
2. Sensitivity: detection limit 1.0pg/ml
3. Fast batch detection: 80-88 samples can be test in half and a hour
4. Convenient operation
5. Open reagents: apply to universal Microplate Chemiluminescence Analyzer
6. User-friendly operation: each solution packed separately, marked with different color, avoid mistaken choosing reagent
If you are interested, please contact us per.service003@perlong.com.cn

2016年6月13日星期一

elisa microplate washer DNX-9620

Elisa reader and washer combines pressure washing,rinse distance,washing time, the shock, vortex, the bottom of the wash, two aspiration, continuous washing and other methods to increase the selection of specifications and other porous shape. Elisa reader and washer has been widely used in hospitals, blood banks, health and epidemic prevention station, reagent plant, laboratory medium currently.

Features of elisa microplate washer (DNX-9620)
1.The  elisa washer machine has a liquid crystal display. You can perfectly complete all your work just according to the instrument's prompts.
2.Setting and operating are easy and straightforward. It is a highly automated instrument, and it enables you to program by yourselve.
3.The elisa washer machine saves previously-set programs in the memory so that you can use them conveniently.
4.The elisa washer machine gives you a quiet working  circumstance in the hospital laboratory.
If you are interested, please contact us per.service003@perlong.com.cn

patient monitor device JP2000-09

JP2000-09 patient monitor is a smart monitor with original appearance, small size and light weight.The embedded system and low power consuming design make JP2000-09 handheld patient monitor more stable and safe.The advanced technology and modern monitoring method distinguish JP2000-09 patient monitor from others and offer the most at the best price.

Adapt to: Suitable for adult child and baby (no fetus). Can work in ICU, operation room, ward, ambulance.(patient monitor device)
Elemental functions: Can monitor the patient sign of ECG, Respiration, NIBP, SpO2, Heart Rate, Temperature. With Li-ion battery inside and can work without AC-power for 3 hours.
Optional functions: Can add portable printer
If you are interested, please contact us per.service003@perlong.com.cn

chemiluminescence immunoassay analyzer FIA8200

1.Multi-channel testing :1-5 channels.
2.Identify the test project automatically.
3.Infrared barcode scanning.
4.User friendly interface, touch screen operation.
5.Laser source, high strength, high stability.
6.Portable design, easy operation.
7.Software upgrade automatically.

Advantage of chemiluminescence immunoassay analyzer FIA8200
1.High accurate result using fluorescence immunoassay quantitative analysis method.
2.The specific5 channels
3.Sample: serum, plasma, whole blood, urine
4.Barcode scan function, automatic test item identification, software upgrade via remote control.
5.10 000sample datastorage.
The voltage change of same concentration test kit within one hour should not exceed±10%
If you are interested, please contact us per.service003@perlong.com.cn

CPAP ventilator machine NLF-200C

Baby ventilator machine is used for newborn baby with stronger spontaneous breath and slightly respiratory failure ,and applies to pediatric clinics for NCPAP oxygen uptake.adjustment precision.

Main technical specification of CPAP ventilator machine NLF-200C
1. Environment conditions
Working environment
Ambient temperature 5 ℃~ 40 ℃
Relative humidity ≤80 %
Atmospheric pressure 960 hPa~1040 hPa
Storage and transportation environment
Ambient temperature -10 ℃~+40 ℃
Relative humidity ≤90 %
Atmospheric pressure 860 hPa~1060 hPa
2. Classification
I class,built-in power supply equipment
B class application part
Normal equipment
Continuous operation
Sterilizable(Refer to Chapter 9 of clearance and sterilization)
3. Gas supply
Gas source O2(For medical use)
Air(For medical use)
Rated working pressure 350 kPa
Output pressure of regulator 350 kPa±50 kPa (300 kPa~400 kPa)
4. Power supply
Voltage ~220 V±22 V
Frequency 50 HZ±1 HZ
Input power 900VA
——Main unit 8 W
——Air compressor 670 W
Fuse
——AC power for main unit 5T T1AL 250V
——Auxliary power 5T T1AL 250V
——AC power for air compressor 5T T6.3AL 250V
——AC power for machine 5T T10AL 250V
5. Electromagnetism compatibility
Cell phone and other radiation equipment used near the machine will cause unexpected problem
to the ventilator.
The other equipment added to ventilator will lead to disturbance to the machine. Before used to
the patient, check if the machine works normally under the set values.
6. Parameter adjustment
FiO2
——Adjusting range 21 % ~ 100 %
——Accuracy ± 15 %
CPAP adjusting range 0 cmH2O ~ 15 cmH2O.
Continuous flow adjusting range 2 L/min ~ 20 L/min
7. Parameter monitoring range
FiO2
——Adjusting range 15 % ~ 100 %
——Accuracy ± 5 %
CPAP/airway pressure
——Monitoring range 0 cmH2O ~ 60 cmH2O
——Accuracy ±(2 % full scale + 4 % actual value)
Continuous flow
——Monitoring range 2 L/min ~ 20 L/min
——Accuracy ≥3 L/min:± 20 %
<3 L/min:± 0.6 L/min
8. Technical specification of compressor
Rated output pressure: 0.35 MPa±0.05 MPa(350 kPa±50 kPa)
Continuous output flow ≥25 L/min when output pressure is 0.35MPa
Peak flow: ≥120 L/min
Dew point temperature ≤5 ℃
Alarm for high heat There is sound alarm and light alarm when the compressed
If you are interested, please contact us per.service003@perlong.com.cn

laboratory reagents hs-CRP

Clinical Application of clinical reagents
1.Effective and independentpredicate biomarker of cardiovasculardisease
2.Prediction of myocardial ischemia recurrence risk and death risk of ACS
3.Evaluation of unstable angina pectoris (UA) diagnosis and prognosis

Advantage of laboratory reagents:
1.High sensitivity:Cut-off value ≤2.5ng/ml
2.Fast diagnosis: 15min completedsample testing
3.Easy operate: using serum, plasma or whole blood sample with high accuracy.
hs-CRP Quantitative Detection Kit (Fluoroimmunoassay chromatography) : 10 tests / 25 tests / 50 tests
If you are interested, please contact us per.service003@perlong.com.cn

digital x ray system PLD7200A

Usages of DR x-ray system 
This dr x-ray system is available for medical teaching, research, medical units for X-ray spot film gastrointestinal photography, remote compartment, and other traumatic perspective X-ray photography and other routine check.The dr x-ray system can be apply to the esophagus, chest, stomach, abdomen, limbs for fluoroscopy and spot film photography.

Features of digital x ray system PLD7200A 
1.One-step workstation from registration to documentation can easily follow the clinical workflow.
2.DICOM 3.0 interface permits to connect PACS network & dry film printer in hospital.
3.Compact,floor-mounted,U-arm design,fits into smaller rooms without the need of ceiling support structures,and can be installed fast.
If you are interested, please contact us per.service003@perlong.com.cn